Control Unit for 2 hand lamps.

Art.No.: 1165

Used for rotating and vibrating speed measurement as well as for the observation of fast moving periodic or non-periodic mechanisms at two from each other separately located fields of events at the same time; for instance in printing, paper, labelling and packaging industries etc. IC/CMOS-technology, longtime stability, transparent dial with 3 linear scales for precise frequency adjustment, signal control buttons for easy operation. Hand lamps can be controlled by additional signal pushbutton switches operated either individually or both at the same time without power drop.

General Data
Light Source : 2 pcs. external hand lamp model 900.00 with flash bulb (control unit without built-in flash bulb)
Flash bulb : 4pin socket-mounted Xenon-longlife, glass tube protected, model MS 300, Art.No.: 10058
Light intensity : approx. 700 Lux in 50cm distance from reflector (beam axis)
Flash duration : approx. 2-7µs
Frequency range : 2,5 - 300 Hz = 150 - 18.000 RPM (min-1)
subdivided into 3 overlapping ranges
1.) 2,5 - 20 Hz = 150 - 1200 RPM (min-1)
2.) 16,6 - 83,3 Hz = 1000 - 5000 RPM (min-1)
3.) 80 - 300 Hz = 4800 - 18000 RPM (min-1)
Trigger action : internal oscillator or external triggering
selected by signal control push button
- Internal control : by dial potentiometer
- External control : by contact or pulse signals
Phase shifter : built-in or seperat unit on request
Display : reading in Hz (flashes per sec.) or RPM (min-1) by parallax-free scale setting.
Accuracy : ± 2% of the set value
Flash power control / range switching: by change of frequency range via signal control push button
Input for external triggering : 6-pole DIN female connector
Technical Data
Power supply : 230V - 250V AC, 50-60 Hz or 115V AC, 50-60 Hz (on request)
Housing : sheet-steel metal with carrying handle
Dimensions : 200 x 125 x 155 mm
Weight : approx. 2,8 kg
Notice : 2 pcs. hand lamp model 900.00 included.
Connection box (2 B.C. sockets) on small side of control unit.
Length of cable 2.50 m (standard) - 
up to max. 10 m on request
Male connector for external triggering included.
Download

Instruction Manual

Data Sheet